ABB CM measuring and monitoring relays supervise electrical supplies, motor temperature and other operating conditions in control systems. Depending on the device, they detect an abnormal condition or a selected threshold and switch output contacts for indication or control. Choose the monitoring function first, then confirm the complete model, input conditions and output-contact duty.

This page contains 135 existing model and ABB code references covering several CM monitoring functions and related insulation-monitoring coupling units. The families have different inputs, supply arrangements and settings; a rating or feature of one CM device must not be applied to the entire range.

Monitoring Purpose & Applications

CM products serve different monitoring tasks in machinery, motor-control panels, power-distribution controls and process equipment. A voltage relay, a temperature relay and a liquid-level relay use different measuring inputs and cannot be selected by the CM prefix alone. Their output contacts form part of the control or alarm circuit; the connected switching and protective equipment must also be selected for the application.

Monitoring Functions in the Existing Model List

  • Voltage and current: listed CM-ESS/CM-EFS voltage references and CM-SRS/CM-SFS current references support monitoring of electrical signals. Over/under or window monitoring, AC/DC input suitability and adjustable ranges depend on the device.
  • Three-phase supplies: the table includes CM-MPS, CM-MPN, CM-PFS, CM-PVS, CM-PAS and CM-PSS references. Available functions include phase sequence, phase loss, voltage limits or phase unbalance, depending on the model. Confirm whether neutral is required and which faults the selected device detects.
  • Motor thermistor protection: CM-MSS references monitor motor-winding temperature through PTC sensors. Check sensor-circuit requirements, fault detection and reset behavior in the exact product instructions. This is different from measuring motor load current with an overload relay.
  • Temperature monitoring: CM-TCS and CM-TCN references evaluate temperature sensors. Confirm the supported sensor, number of inputs, measurement range, thresholds and output assignment. Display, communications and configuration features are version-specific.
  • Liquid level: CM-ENS and CM-ENE references are for conductive liquids, with functions such as filling, draining or level alarms depending on the version. Check liquid conductivity, electrode arrangement and sensitivity; this is not a universal measurement method for every fluid.
  • Insulation monitoring: CM-IWS and CM-IWN references monitor insulation resistance in unearthed IT systems. Match the device to the network’s AC/DC characteristics and permitted voltage/capacitance conditions. These devices are not interchangeable with residual-current circuit breakers.

CM-IVN.S and CM-IVN.P are coupling units: ABB lists them as related insulation-monitoring devices, rather than independent monitoring-relay bodies. They remain in the existing table; confirm the required monitoring relay and coupling arrangement together. Earlier CM references also remain available for identification, with their exact specifications checked individually.

Inputs, Supply & Output Contacts

Distinguish the monitored circuit or sensor input from the control supply. Some versions are powered by the monitored circuit; others require a separate supply. Confirm voltage, AC/DC suitability, frequency and terminal wiring from the selected device’s diagram. For current inputs, check the permitted measuring input and any required transformer arrangement in the exact instructions.

Confirm the required threshold or window, hysteresis and response/start-up delay where adjustable. Check fault memory, automatic/manual reset and open- or closed-circuit operating principle where applicable. Available settings and diagnostic functions vary between product families and versions.

Choose the required normally open/closed or changeover contacts and check their rating for the actual load and utilization category. A resistive-load rating does not establish suitability for every inductive coil. Match the output to the alarm, contactor or controller interface and check the required fault-state behavior.

Confirming a CM Selection & Requesting a Quote

Send the full product model, ABB order code or article number, quantity and destination country. For a new selection, include the monitoring task, system and control-supply voltage, AC/DC and frequency, wiring including neutral where relevant, sensor/electrode details, thresholds, delays, reset behavior and required output contacts. Confirm terminal type, installation space, ambient conditions and applicable regional approvals using the exact product data.

For an existing installation, add a readable nameplate photo and wiring or equipment details. Do not select an older reference or a proposed replacement solely by matching a headline voltage or the CM family name.

Related pages: Relays & Monitoring; CT Time Relays for timing functions; and Contact for quotation.

ABB references: Monitoring and control overview; temperature monitoring; liquid-level monitoring; insulation monitoring.

Illustrated CM Family Examples

CM-MPS
CM-PFS
CM-PVS
CM-EFS
CM-SRS
CM-UFD

CM-UFD is a separate grid-feeding monitoring application. It is shown in the portfolio illustration and examples above, but no CM-UFD model is included in the 135-row table below; its requirements and regional grid rules need a separate product check.

ABB CM Models & Order Codes

Search the 135 existing references by model or ABB code. The Vendor Code column preserves the listed order codes, including related CM-IVN coupling units. Confirm the complete designation and its matching product data before selection. Send the model, code, quantity, destination and monitoring requirements to Contact for quotation.

ModelVendor Code
CM-PFS.S1SVR730824R9300
CM-IVN.S1SVR750669R9400
CM-IVN.P1SVR760669R9400
CM-PFS.P1SVR740824R9300
CM-IWN.1S1SVR750660R0200
CM-IWS.2S1SVR730670R0200
CM-IWS.1S1SVR730660R0100
CM-IWS.2P1SVR740670R0200
CM-EFS.2P1SVR740750R0400
CM-ESS.MP1SVR740830R0500
CM-IWN.1P1SVR760660R0200
CM-IWS.1P1SVR740660R0100
CM-TCS.11S1SVR730740R0100
CM-MPN.62S1SVR750488R8300
CM-MPN.52S1SVR750487R8300
CM-MPS.21S1SVR730885R3300
CM-PAS.31S1SVR730774R1300
CM-PVS.41S1SVR730794R3300
CM-PSS.31S1SVR730784R2300
CM-MPS.11S1SVR730885R1300
CM-PVS.31S1SVR730794R1300
CM-PAS.41S1SVR730774R3300
CM-MPS.43S1SVR730884R4300
CM-MPS.41S1SVR730884R3300
CM-MPN.72S1SVR750489R8300
CM-PSS.41S1SVR730784R3300
CM-MPS.31S1SVR730884R1300
CM-MPS.23S1SVR730885R4300
CM-PVS.81S1SVR730794R2300
CM-MPS.41P1SVR740884R3300
CM-MPS.43P1SVR740884R4300
CM-MPN.72P1SVR760489R8300
CM-SFS.21P1SVR740760R0400
CM-TCS.11P1SVR740740R0100
CM-PAS.31P1SVR740774R1300
CM-MPS.11P1SVR740885R1300
CM-PSS.31P1SVR740784R2300
CM-MPN.52P1SVR760487R8300
CM-MPS.31P1SVR740884R1300
CM-PSS.41P1SVR740784R3300
CM-TCS.23P1SVR740740R9300
CM-PVS.41P1SVR740794R3300
CM-TCS.22P1SVR740740R9200
CM-MPS.23P1SVR740885R4300
CM-TCS.21P1SVR740740R9100
CM-PAS.41P1SVR740774R3300
CM-MPS.21P1SVR740885R3300
CM-TCS.13P1SVR740740R0300
CM-PVS.31P1SVR740794R1300
CM-MPN.62P1SVR760488R8300
CM-SRS.M1P1SVR740840R0600
CM-TCS.12P1SVR740740R0200
CM-MSS.21S1SVR730722R1400
CM-MSS.33S1SVR730712R2200
CM-MSS.13S1SVR730700R2100
CM-MSS.51S1SVR730712R1300
CM-MSS.33P1SVR740712R2200
CM-MSS.32S1SVR730712R0200
CM-MSS.12P1SVR740700R0100
CM-MSS.22P1SVR740700R0200
CM-MSS.31S1SVR730712R1400
CM-MSS.21P1SVR740722R1400
CM-MSS.23P1SVR740700R2200
CM-MSS.11P1SVR740720R1400
CM-MSS.32P1SVR740712R0200
CM-MSS.12S1SVR730700R0100
CM-MSS.41P1SVR740712R1200
CM-MSS.11S1SVR730720R1400
CM-MSS.13P1SVR740700R2100
CM-MSS.22S1SVR730700R0200
CM-MSS.41S1SVR730712R1200
CM-MSS.23S1SVR730700R2200
CM-MSS.31P1SVR740712R1400
CM-MSS.51P1SVR740712R1300
CM-ENS.11S1SVR730850R0100
CM-ENS.21S1SVR730850R0200
CM-ENS.31S1SVR730850R0300
CM-ENS.13S1SVR730850R2100
CM-ENS.23S1SVR730850R2200
CM-ENS.13P1SVR740850R2100
CM-ENS.11P1SVR740850R0100
CM-ENS.21P1SVR740850R0200
CM-ENS.31P1SVR740850R0300
CM-ENS.23P1SVR740850R2200
CM-TCN.011S1SVR750740R0110
CM-TCN.011P1SVR760740R0110
CM-ESS.2P 110-130 V AC1SVR740831R0400
CM-ESS.2P 220-240 V AC1SVR740831R1400
CM-ESS.1P 220-240 V AC1SVR740831R1300
CM-SRS.11P 220-240 V AC1SVR740841R1200
CM-ESS.1P 24-240 V AC/DC1SVR740830R0300
CM-SRS.21P, 220-240 V AC1SVR740841R1400
CM-ESS.2P 24-240 V AC/DC1SVR740830R0400
CM-SRS.21P 24-240 V AC/DC1SVR740840R0400
CM-SRS.11P 24-240 V AC/DC1SVR740840R0200
CM-MSE, 1no, auto reset, 24VAC1SVR550805R9300
CM-TCS.22S, 0...+100°C, 24VAC/DC1SVR730740R9200
CM-TCS.23S, 0...+200°C, 24VAC/DC1SVR730740R9300
CM-TCS.21S, -50...+50°C, 24VAC/DC1SVR730740R9100
CM-MSE, 1no, auto reset, 110-130VAC1SVR550800R9300
CM-ESS.1S, 1c/o, 3-600V, 220-240VAC1SVR730831R1300
CM-ESS.2S, 2c/o, 3-600V, 220-240VAC1SVR730831R1400
CM-TCS.13S, 0...+200°C, 24-240VAC/DC1SVR730740R0300
CM-TCS.12S, 0...+100°C, 24-240VAC/DC1SVR730740R0200
CM-MSE, 1no, auto reset, 220-240 VAC1SVR550801R9300
CM-SRS.21S, 2c/o, 3mA-1A, 220-240VAC1SVR730841R1400
CM-SRS.11S, 1c/o, 3mA-1A, 220-240VAC1SVR730841R1200
CM-ESS.2S, 2c/o, 3-600V, 110-130VAC1SVR730831R0400
CM-ENE MIN, liquid level, 1no, 24VAC1SVR550855R9500
CM-ENE MAX, liquid level, 1no, 24VAC1SVR550855R9400
CM-PBE, phase fault, 1no, 380-440VAC1SVR550882R9500
CM-PBE, phase fault, 1no, 220-240VAC1SVR550881R9400
CM-PFE, phase seq, 1 c/o, 208-440VAC1SVR550824R9100
CM-ESS.MS, 2c/o, 3-600V, 24-240VAC/DC1SVR730830R0500
CM-ESS.1S, 1c/o, 3-600V, 24-240VAC/DC1SVR730830R0300
CM-ESS.2S, 2c/o, 3-600V, 24-240VAC/DC1SVR730830R0400
CM-SRS.22S, 2c/o, 0.3-15A, 220-240VAC1SVR730841R1500
CM-SRS.12S, 1c/o, 0.3-15A, 110-130VAC1SVR730841R0300
CM-EFS.2S, 2c/o, 3-600V, 24-240VAC/DC1SVR730750R0400
CM-SRS.12S, 1c/o, 0.3-15A, 220-240VAC1SVR730841R1300
CM-SRS.22S, 2c/o, 0.3-15A, 110-130VAC1SVR730841R0500
CM-PVE, 1no, w/neutral mon, 185-265VAC1SVR550870R9400
CM-SRS.M1S, 2c/o, 3mA-1A, 24-240VAC/DC1SVR730840R0600
CM-SRS.21S, 2c/o, 3mA-1A, 24-240VAC/DC1SVR730840R0400
CM-SFS.21S, 2c/o, 3mA-1A, 24-240VAC/DC1SVR730760R0400
CM-SRS.22S, 2c/o, 0.3-15A, 24-240VAC/DC1SVR730840R0500
CM-SRS.M2S, 2c/o, 0.3-15A, 24-240VAC/DC1SVR730840R0700
CM-SFS.22S, 2c/o, 0.3-15A, 24-240VAC/DC1SVR730760R0500
CM-SRS.11S, 1c/o, 3mA-1A , 24-240VAC/DC1SVR730840R0200
CM-SRS.12S, 1c/o, 0.3-15A, 24-240VAC/DC1SVR730840R0300
CM-ENE MAX, liquid level, 1no,220-240VAC1SVR550851R9400
CM-ENE MIN, liquid level, 1no,220-240VAC1SVR550851R9500
CM-ENE MIN, liquid level, 1no,110-130VAC1SVR550850R9500
CM-ENE MAX, liquid level, 1no,110-130VAC1SVR550850R9400
CM-PVE, 1no, w/o neutral mon, 320-460VAC1SVR550871R9500