ABB CMS current sensors monitor individual branches in electrical distribution systems. The range includes open-core and solid-core sensors with several mounting arrangements. Choose the current range, core type and mounting suffix together, then verify the controller and connection arrangement.
Open-Core, Solid-Core & Mounting Options
The current InSite catalogue lists open-core CMS-12x sensors and solid-core CMS-10x/CMS-20x sensors. PS mounting is intended for the specified DIN-rail protection devices and SMISSLINE arrangement; S8 versions mount on ABB S800 high-performance breakers; DR versions mount on DIN rail; CA versions use a cable tie. LA is a separately documented open-core mounting arrangement. Mounting suffixes are not interchangeable merely because the current range matches.
Branch Monitoring or Energy Metering?
A CMS current sensor is a system component, not a standalone billing energy meter or a conventional 1 A/5 A current transformer. Confirm the bus connection, controller support, firmware, current range, conductor clearance and mounting method against ABB’s documentation. Current sensing alone does not establish a fiscal-energy measurement capability. Existing CMS600/CMS700 control-unit enquiries require a separate exact-model documentation check; no lifecycle or replacement claim is made here.
Related range: ABB InSite SCU100/SCU200 systems.
Models & ABB Order Codes
These documented references support model identification and procurement enquiries. They are not an exhaustive regional catalogue or a statement of inventory or availability.
Request a quotation with the full model and installation requirements.
| Product Model | ABB Order Code | Rated Current |
|---|---|---|
| CMS-120LA | 2CCA880225R0001 | 80 A |
| CMS-121LA | 2CCA880226R0001 | 40 A |
| CMS-122LA | 2CCA880227R0001 | 20 A |
| CMS-120PS | 2CCA880210R0001 | 80 A |
| CMS-121PS | 2CCA880211R0001 | 40 A |
| CMS-122PS | 2CCA880212R0001 | 20 A |
| CMS-120DR | 2CCA880240R0001 | 80 A |
| CMS-121DR | 2CCA880241R0001 | 40 A |
| CMS-122DR | 2CCA880242R0001 | 20 A |
| CMS-120CA | 2CCA880220R0001 | 80 A |
| CMS-121CA | 2CCA880221R0001 | 40 A |
| CMS-122CA | 2CCA880222R0001 | 20 A |
| CMS-100PS | 2CCA880100R0001 | 80 A |
| CMS-101PS | 2CCA880101R0001 | 40 A |
| CMS-102PS | 2CCA880102R0001 | 20 A |
| CMS-100S8 | 2CCA880124R0001 | 80 A |
| CMS-101S8 | 2CCA880125R0001 | 40 A |
| CMS-102S8 | 2CCA880126R0001 | 20 A |
| CMS-100DR | 2CCA880128R0001 | 80 A |
| CMS-101DR | 2CCA880129R0001 | 40 A |
| CMS-102DR | 2CCA880130R0001 | 20 A |
| CMS-100CA | 2CCA880107R0001 | 80 A |
| CMS-101CA | 2CCA880108R0001 | 40 A |
| CMS-102CA | 2CCA880109R0001 | 20 A |
| CMS-200S8 | 2CCA880136R0001 | 160 A |
| CMS-201S8 | 2CCA880137R0001 | 80 A |
| CMS-202S8 | 2CCA880138R0001 | 40 A |
| CMS-200DR | 2CCA880132R0001 | 160 A |
| CMS-201DR | 2CCA880133R0001 | 80 A |
| CMS-202DR | 2CCA880134R0001 | 40 A |
| CMS-200CA | 2CCA880117R0001 | 160 A |
| CMS-201CA | 2CCA880118R0001 | 80 A |
| CMS-202CA | 2CCA880119R0001 | 40 A |
ABB Technical Documentation
ABB InSite Catalogue: Current Sensors (PDF) — Rev. E, September 2026; sensor ordering tables, printed pages 45–46.
Request a Quote