Energy Meters & Measurement

ABB CMS current sensors monitor individual branches in electrical distribution systems. The range includes open-core and solid-core sensors with several mounting arrangements. Choose the current range, core type and mounting suffix together, then verify the controller and connection arrangement.

Open-Core, Solid-Core & Mounting Options

The current InSite catalogue lists open-core CMS-12x sensors and solid-core CMS-10x/CMS-20x sensors. PS mounting is intended for the specified DIN-rail protection devices and SMISSLINE arrangement; S8 versions mount on ABB S800 high-performance breakers; DR versions mount on DIN rail; CA versions use a cable tie. LA is a separately documented open-core mounting arrangement. Mounting suffixes are not interchangeable merely because the current range matches.

Branch Monitoring or Energy Metering?

A CMS current sensor is a system component, not a standalone billing energy meter or a conventional 1 A/5 A current transformer. Confirm the bus connection, controller support, firmware, current range, conductor clearance and mounting method against ABB’s documentation. Current sensing alone does not establish a fiscal-energy measurement capability. Existing CMS600/CMS700 control-unit enquiries require a separate exact-model documentation check; no lifecycle or replacement claim is made here.

Related range: ABB InSite SCU100/SCU200 systems.

Models & ABB Order Codes

These documented references support model identification and procurement enquiries. They are not an exhaustive regional catalogue or a statement of inventory or availability.

Request a quotation with the full model and installation requirements.

Product Model ABB Order Code Rated Current
CMS-120LA2CCA880225R000180 A
CMS-121LA2CCA880226R000140 A
CMS-122LA2CCA880227R000120 A
CMS-120PS2CCA880210R000180 A
CMS-121PS2CCA880211R000140 A
CMS-122PS2CCA880212R000120 A
CMS-120DR2CCA880240R000180 A
CMS-121DR2CCA880241R000140 A
CMS-122DR2CCA880242R000120 A
CMS-120CA2CCA880220R000180 A
CMS-121CA2CCA880221R000140 A
CMS-122CA2CCA880222R000120 A
CMS-100PS2CCA880100R000180 A
CMS-101PS2CCA880101R000140 A
CMS-102PS2CCA880102R000120 A
CMS-100S82CCA880124R000180 A
CMS-101S82CCA880125R000140 A
CMS-102S82CCA880126R000120 A
CMS-100DR2CCA880128R000180 A
CMS-101DR2CCA880129R000140 A
CMS-102DR2CCA880130R000120 A
CMS-100CA2CCA880107R000180 A
CMS-101CA2CCA880108R000140 A
CMS-102CA2CCA880109R000120 A
CMS-200S82CCA880136R0001160 A
CMS-201S82CCA880137R000180 A
CMS-202S82CCA880138R000140 A
CMS-200DR2CCA880132R0001160 A
CMS-201DR2CCA880133R000180 A
CMS-202DR2CCA880134R000140 A
CMS-200CA2CCA880117R0001160 A
CMS-201CA2CCA880118R000180 A
CMS-202CA2CCA880119R000140 A

ABB Technical Documentation

ABB InSite Catalogue: Current Sensors (PDF) — Rev. E, September 2026; sensor ordering tables, printed pages 45–46.

Request a Quote

Send the full CMS model and ABB order code, quantity and destination country. Include current range, conductor size, mounting arrangement, control-unit model and bus layout. For an existing installation, provide the sensor and controller nameplates.

Contact us about this ABB measurement range